ENKA SET NATURA
-->
PDF INSTUCTION
PDF INSTUCTION ECOMAX 800W |
FUEL - [PALLET, BOO-MASS ]
ENKA SET Natura with auto-ignition system is the most recent solution of our company aimed at ecological burning of solid fuel, like Pellet
The fuel is delivered from high volume 250 - 1000 kg basket, or from direct fuel box, without any basket. Pellet is supplied with screw conveyor and fed into the combustion chamber. Fuel box/basket can be practically located in a comfortable part of Boiler House or even outside, due to the flexible delivery system between the burner and storage. One feeding enables 7 to 30 days of operation, dependent on heat requirements. Burner has auto-disposal system to obtain necessary fuel ignited with auto-ignition device. During operation, the burned remains are pushed into the ash compartment, which may be emptied even once in several months.
Main advantages of the Boiler are:
- auto-ignition system
- photocell flame control
- large and comfortable basket
- special boiler exchanger
- comfortable washing system
- very good insulation
- low heat insertion during start-up and stopping.
- self-cleaning burner, with Fuzzy Logic, quieter and more economic
- burner operative temperature control enables the highest safety
- AUTOSTART remembers the last settings after the disruption of power
- auto-cleaning functionality automatically removes sediments from burner grate
Boiler exchanger is made of burner chamber and exchanging part enabling high efficiency.
The exchanger is divided into four vertical channels. ENKA SET Natura Model is normally equipped with room thermostat, weather sensor and all other sensors necessary for each type of installations. 5 year basic warranty for Boiler, with additional 10 year warranty for welding joints
ENKA SET NATURA |
Measurement unit |
12KW | 18KW | 26KW | 36KW | 50KW |
RANGE OF POWER |
KW |
6-15 | 12-24 | 20-32 | 28-42 | 32-58 |
LIVING SPACE SERVED |
m |
do 160 |
do 220 |
do 280 |
do 400 |
do 600 |
SINGLE FUEL BATCH |
kg |
od 300 |
od 300 |
od 300 |
od 300 |
od 300 |
MAX. HEATATING EFFICIENCY |
% |
88 |
88 |
91 |
91 |
91 |
OPERATIONAL PRESSURE |
Mpa |
0,10 lub 0,25(opcja) |
||||
REQUIRED CHIMNEY DRAW |
Pa |
20 |
24 |
28 |
32 |
38 |
BOILER WEIGHT |
kg |
280 |
380 |
450 |
520 |
620 |
WATER VOLUME |
L |
70 |
80 |
120 |
150 |
200 |
REQUIRED CHIMNEY DIAMETER |
∅ |
180 |
180 |
200 |
200 |
200 |
MIN. HEIGHT OF CHIMNEY |
m |
5 |
6 |
8 |
8 |
10 |
BOILER WIDTH |
cm |
45 |
48 |
48 |
52 |
62 |
BOILER DEPTH |
cm |
46 |
54 |
56 |
67 |
120 |
BOILER HEIGHT |
cm |
100 |
118 |
148 |
160 |
140 |
RETURN CIRCULATION DIAMETER |
cal |
11/4 |
||||
FLUE DIAMETER |
cm |
130 |
130 |
180 |
200 |
220 |